From jpric--(at)--tdcs2.intel.com Thu Sep 5 17:43:07 CDT 1996
Article: 14166 of rec.audio.tubes
From: Jack Price Newsgroups: rec.audio.tubes
Subject: Re: Substituting Cap values in Fender amps ?
Date: Thu, 05 Sep 1996 14:08:31 -0700
Organization: Intel
Lines: 29
Message-ID: <322F414F.41C--(at)--tdcs2.intel.com>
References: <322DD4BB.74C--(at)--rols.com>
NNTP-Posting-Host: ptdi127.ra.intel.com
Mime-Version: 1.0
Content-Type: text/plain; charset=us-ascii
Content-Transfer-Encoding: 7bit
X-Mailer: Mozilla 2.02 (X11; I; AIX 2)
loizeaux wrote:
>
> Since I can't find 70uf--(at)--350vdc axial caps, what other values would be
> acceptable in blackface Fender amps? I can't even find Sprague 80ufs,
> and I don't know how high I can go before I start affecting performance.
> These caps are wired in parallel and work closest to the rectifier and
> handle 450 volts. Thanks for any info.
>
> Tom
Tom,
Most of us are replacing the 70uF--(at)--50v with Sprague
"Atomic Blue" cans at 100uf--(at)--50v. Sprague part
number is TVA1620. Perfect fit too! E-mail Mojo Tone
for a dealer nearest you.
jp
--
By Day:
Intel Portland Technology Development
Jack A. Price Group: P6CS
Phone: (503) 613-8116 FAX: (503) 613-8261
MS: RA1-303 EMAIL: jpric--(at)--tdcs2.intel.com
By Nite:
PriceLe$$ Amp Restoration
Specializing in Fender Amp Restoration/Mods and Custom Designs
(503) 641-7146
VibroClon--(at)--rodigy.com